Version 2/3/2014 INSTALLATION, OPERATION & MAINTENANCE MANUAL KB SERIES TOP DISCHARGE HEAVY DUTY DEWATERING WITH AGITATOR Electric Subm
10 TYPICAL AUTOMATIC DEWATERING INSTALLATION NOTE: Maximum recommended starts should not exceed 10 times per hour. Float switches (wired into t
11 THREE PHASE WIRING INSTRUCTION FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. “Risk of electric
12 diagram), is connected to a valid ground, momentarily energize the pump, observing the directions of kick back due to starting torque. Rotation
13 5. Excessive voltage drops due to long cables. 6. Three phase only; pump running backwards, check rotation. SERVICING YOUR SUBMERSIBLE PUMP
14 9) Remove the screws that hold the oil chamber cover in place & remove the oil. 10) Replace the mechanical seal if necessary. 11) Replace
15 EXPLODED VIEW OF KB55, 55H, 75, 75H, 110, 110H
16 KB SERIES PARTS LIST Pump Model KB55 KB55H KB75 KB75H KB110 KB110HPos. No. Part Description Item # Item # Item # Item # Item # Item #01 Strainer
17 KB SERIES PARTS LIST 26 Pump Top Cover 203133 203133 203134 203133 203134 20313426-1 O-Ring (Kit Only) Kit Kit Kit Kit Kit Kit27 Power Cord Se
18 THREE PHASE WIRING DIAGRAMS 230V (5 LEAD) MODELS KB55, 55H, 75, 75H, 110, 110H
19 460V (5 LEAD) MODELS KB55, 55H, 75, 75H, 110, 110H
20 575V (5 LEAD) MODELS KB55, 55H, 75, 75R, 110, 110H
21 SEAL MINDER
22
23 BJM PUMPS, LLC 123 Spencer Plain Road Old Saybrook, CT 06475, U.S.A. WARRANTY AND LIMITATION OF LIABILITY Unless otherwise expressly authori
START-UP REPORT FORM START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a
START-UP REPORT FORM presence? Are guide rails exactly vertical? Yes No Is base elbow installed level? Yes No Liquid level controls: Model Is
START-UP REPORT FORM Voltage supply at panel line connection, pump on L1-L2 L2-L3 L3-L1 Amperage load connection, pump on L1 L2 L3 FINAL CHECK Is p
NOTES:
BJM Pumps & Seal Minder is a registered trademark of BJM Pumps, LLC Copyright © 2006-2013 BJM Pumps, LLC. All rights reserved.
TABLE OF CONTENTS INTRODUCTION ...
4 INTRODUCTION This Installation, Operation and Maintenance manual provides important information on safety and the proper inspection, disas
5 HSAFETY Pump installations are seldom identical. Each installation and application can vary due to many different factors. It is the own
6 INSPECTION Review all safety information before servicing pump. The following are recommended installation practices/procedures for the pump. I
7 PUMP INSTALLATION KB Series pumps have been evaluated for use with water or water based solutions. Please contact the manufacturer for addition
8 PUMP ROTATION Two ways to check the correct pump rotation: 1. By looking at the impeller; the rotation of the impeller should be counter cloc
9 PUMP OPERATION This pump is designed to handle dirty water that contains some solids. It is not designed to pump volatile or flammable liq
Comments to this Manuals