Version 2/12/2014 INSTALLATION, OPERATION & MAINTENANCE MANUAL FARHENHEIT™ S-F& SX-F SERIES SIDE DISCHARGE Electric Submersible Pumps Sin
10 TYPICAL AUTOMATIC WASTEWATER INSTALLATION NOTE: Maximum recommended starts should not exceed 10 times per hour. STOPPING To stop the pump (manu
11 Figure 1 SX750F-115 control Figure 2 SX750F-230, S1500F-230 and SX1500F-230 control
12 OPTIONAL FLOAT CONNECTION BJM Pumps utilizes a control for all of the single phase “F” series pumps. The wiring diagram included in this manual (
13 PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY 1. Discharge line clogged, restricted or hose kinked. Check discharge hose/pipe. 2. Worn impeller
14 3) Remove the screws that hold the bottom plate in place. 4) Remove bottom plate. 5) Remove screws holding the suction cover. 6) Remove the
15 EXPLODED VIEW OF S1500C-F
16 EXPLODED VIEW OF SX750CSS-F AND SX1500CSS-F
17 S-F SERIES PARTS LIST Pump ModelS1500CFPos. No. Part DescriptionItem #01-2 Stand 20198605 Impeller 20209807 Pump Housing 20300808 Oil Chambe
18 SX-F SERIES PARTS LIST Pump Model SX750CSSF SX1500CSSFPos. No. Part DescriptionItem # Item #01-2 Stand 201985 20198705 Impeller 202095 2020970
19 SINGLE PHASE WIRING DIAGRAM 115V & 230V MODELS S1500CF, SX750CSSF & SX1500CSSF
20 SEAL MINDER® - THERMAL MOTOR SENSOR SWITCH (For high temperature single phase pump models) Seal Minder: Also known as a seal failure circuit (
21 BJM PUMPS, LLC 123 Spencer Plain Road Old Saybrook, CT 06475, U.S.A. WARRANTY AND LIMITATION OF LIABILITY Unless otherwise expressly authori
START-UP REPORT FORM START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a
START-UP REPORT FORM Are guide rails vertical? Yes No Is base elbow installed level? Yes No Liquid level controls: Model Is control installed
START-UP REPORT FORM L1-L2 L2-L3 L3-L1 Amperage load connection, pump on L1 L2 L3 FINAL CHECK Is pump secured properly? Yes No Was pump checked f
FARHENHEIT™ is a trademark of BJM Pumps, LLC. BJM Pumps & Seal Minder is a registered trademark of BJM Pumps, LLC Copyright © 2009-2013 BJM Pu
TABLE OF CONTENTS INTRODUCTION ...
4 INTRODUCTION This Installation, Operation and Maintenance manual provides important information on safety and the proper inspection, disassem
5 Hazards or unsafe practices which COULD result in personal injury or product or property damage. These instructions describe the procedure requi
6 INSPECTION Review all safety information before servicing pump. The following are recommended installation practices/procedures for the pump. If
7 PUMP INSTALLATION S-F & SX-F Series pumps have been evaluated for use with water or water based solutions. Please contact the manufac
8 PUMP ROTATION If wired properly to the control, the single phase BJM Pumps S-F and SX-F Series pump should operate with the correct pumping rotati
9 PUMP OPERATION This pump is designed to handle dirty water that contains some solids. It is not designed to pump volatile or flammable liqui
Comments to this Manuals