INSTALLATION, OPERATION & MAINTENANCE MANUAL
FARHENHEIT
S-F& SX-F SERIES
SIDE DISCHARGE
Electric Submersible Pumps
Single Phase
115V & 230V
CAST IRON
SINGLE PHASE
S1500C-F
316 STAINLESS STEEL
SINGLE PHASE
SX750CSS-F
SX1500CSS-F
Read this manual carefully before installing, operating or servicing these pump models.
Observe all safety information. Failure to comply with instructions may result in personal
injury and/or property damage. Please retain these instructions.
Page view 0
1 2 3 4 5 6 ... 25 26

Summary of Contents

Page 1

Version 2/12/2014 INSTALLATION, OPERATION & MAINTENANCE MANUAL FARHENHEIT™ S-F& SX-F SERIES SIDE DISCHARGE Electric Submersible Pumps Sin

Page 2

10 TYPICAL AUTOMATIC WASTEWATER INSTALLATION NOTE: Maximum recommended starts should not exceed 10 times per hour. STOPPING To stop the pump (manu

Page 3 - TABLE OF CONTENTS

11 Figure 1 SX750F-115 control Figure 2 SX750F-230, S1500F-230 and SX1500F-230 control

Page 4

12 OPTIONAL FLOAT CONNECTION BJM Pumps utilizes a control for all of the single phase “F” series pumps. The wiring diagram included in this manual (

Page 5

13 PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY 1. Discharge line clogged, restricted or hose kinked. Check discharge hose/pipe. 2. Worn impeller

Page 6

14 3) Remove the screws that hold the bottom plate in place. 4) Remove bottom plate. 5) Remove screws holding the suction cover. 6) Remove the

Page 7

15 EXPLODED VIEW OF S1500C-F

Page 8

16 EXPLODED VIEW OF SX750CSS-F AND SX1500CSS-F

Page 9

17 S-F SERIES PARTS LIST Pump ModelS1500CFPos. No. Part DescriptionItem #01-2 Stand 20198605 Impeller 20209807 Pump Housing 20300808 Oil Chambe

Page 10

18 SX-F SERIES PARTS LIST Pump Model SX750CSSF SX1500CSSFPos. No. Part DescriptionItem # Item #01-2 Stand 201985 20198705 Impeller 202095 2020970

Page 11 - Figure 1 SX750F-115 control

19 SINGLE PHASE WIRING DIAGRAM 115V & 230V MODELS S1500CF, SX750CSSF & SX1500CSSF

Page 13

20 SEAL MINDER® - THERMAL MOTOR SENSOR SWITCH (For high temperature single phase pump models) Seal Minder: Also known as a seal failure circuit (

Page 14

21 BJM PUMPS, LLC 123 Spencer Plain Road Old Saybrook, CT 06475, U.S.A. WARRANTY AND LIMITATION OF LIABILITY Unless otherwise expressly authori

Page 15 - EXPLODED VIEW OF S1500C-F

START-UP REPORT FORM START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a

Page 16

START-UP REPORT FORM Are guide rails vertical? Yes No Is base elbow installed level? Yes No Liquid level controls: Model Is control installed

Page 17 - S-F SERIES PARTS LIST

START-UP REPORT FORM L1-L2 L2-L3 L3-L1 Amperage load connection, pump on L1 L2 L3 FINAL CHECK Is pump secured properly? Yes No Was pump checked f

Page 19

FARHENHEIT™ is a trademark of BJM Pumps, LLC. BJM Pumps & Seal Minder is a registered trademark of BJM Pumps, LLC Copyright © 2009-2013 BJM Pu

Page 20

TABLE OF CONTENTS INTRODUCTION ...

Page 21

4 INTRODUCTION This Installation, Operation and Maintenance manual provides important information on safety and the proper inspection, disassem

Page 22 - START-UP REPORT FORM

5 Hazards or unsafe practices which COULD result in personal injury or product or property damage. These instructions describe the procedure requi

Page 23

6 INSPECTION Review all safety information before servicing pump. The following are recommended installation practices/procedures for the pump. If

Page 24

7 PUMP INSTALLATION S-F & SX-F Series pumps have been evaluated for use with water or water based solutions. Please contact the manufac

Page 25

8 PUMP ROTATION If wired properly to the control, the single phase BJM Pumps S-F and SX-F Series pump should operate with the correct pumping rotati

Page 26 - FARHENHEIT

9 PUMP OPERATION This pump is designed to handle dirty water that contains some solids. It is not designed to pump volatile or flammable liqui